Laboratory Fume Hood: Types, Functions and How to Choose the Right One
Introduction
A laboratory fume hood is one of the most important pieces of safety equipment in modern laboratories. It is designed to capture and remove hazardous fumes, vapors, gases, and airborne contaminants generated during laboratory experiments and chemical handling.
Unlike ordinary laboratory workbenches, fume hoods provide an enclosed working area with a controlled airflow system to help protect laboratory personnel from exposure to hazardous substances.
Different laboratories have different ventilation requirements. Chemistry laboratories may require ducted fume hoods for chemical experiments, while specialized corrosive environments may benefit from polypropylene (PP) fume hoods. Laboratories with limited exhaust infrastructure may consider ductless systems when the chemical applications are suitable for filtration and recirculation.
Choosing the right laboratory fume hood requires careful consideration of chemical compatibility, airflow performance, exhaust requirements, working dimensions, materials, and applicable safety standards.
In this guide, we will explore the main types of laboratory fume hoods, their functions, structural components, materials, applications, and important factors to consider before purchasing a laboratory fume hood.
1. What Is a Laboratory Fume Hood?

A laboratory fume hood is an enclosed ventilation workstation designed to capture and remove hazardous airborne substances generated during laboratory activities.
It typically consists of an enclosure, movable sash, airflow system, internal baffles, work surface, lighting, and exhaust connection.
The fume hood draws air through its front opening and directs contaminated air away from the operator through an exhaust system or a suitable filtration system.
Main Functions of a Laboratory Fume Hood
1. Protection Against Chemical Exposure
Helps reduce laboratory personnel's exposure to hazardous fumes, vapors, and airborne contaminants when properly designed, installed, and operated.
2. Controlled Airflow
Maintains inward airflow through the working opening to help contain contaminants within the enclosure.
3. Chemical Experimentation
Provides an enclosed working area for handling suitable chemicals and conducting experiments that generate hazardous airborne substances.
4. Exhaust Ventilation
Ducted systems transport contaminated air through an exhaust duct to an appropriate discharge location.
5. Improved Laboratory Safety
Helps create a safer working environment when used together with appropriate laboratory procedures, personal protective equipment, and other engineering controls.
2. Main Types of Laboratory Fume Hoods
Laboratory fume hoods can be classified according to ventilation method, construction material, installation configuration, and intended application.
2.1 Ducted Laboratory Fume Hood
A ducted fume hood is connected to an external exhaust system that removes contaminated air from the laboratory.
It is one of the most commonly used fume hood configurations in chemical laboratories.
Main Features:
External exhaust duct connection
Dedicated exhaust fan or suitable exhaust system
Movable front sash
Internal airflow baffles
Chemical-resistant internal lining
Integrated lighting
Optional water, gas, and electrical services
Advantages:
Suitable for many applications involving hazardous chemical vapors
Continuously removes contaminated air during operation
Does not rely on recirculating filtered air back into the laboratory
Can be configured for different chemical applications
Disadvantages:
Requires exhaust ductwork
Requires suitable exhaust discharge arrangements
Installation can be more complex
Operating costs include exhaust fan energy and conditioned replacement air
Applications:
Chemistry laboratories
Pharmaceutical laboratories
Research laboratories
Industrial testing facilities
Chemical analysis laboratories
Ducted fume hoods are generally preferred for applications involving a wide variety of chemicals, particularly when the chemical hazards or concentrations are difficult to control through filtration alone.
2.2 Ductless Laboratory Fume Hood

A ductless fume hood uses a filtration system to capture selected airborne contaminants and return filtered air to the laboratory.
Depending on the application, filtration systems may use activated carbon, HEPA filters, or other specialized filter media.
Main Features:
Built-in filtration system
No external exhaust duct in standard recirculating configurations
Movable sash
Airflow monitoring
Filter condition monitoring
Replaceable filter cartridges
Advantages:
Does not require conventional external exhaust ductwork
Flexible installation
Can reduce the need to exhaust conditioned room air
Suitable for specific, validated chemical applications
Disadvantages:
Filter compatibility must be carefully evaluated
Filter replacement is necessary
Filter saturation and breakthrough must be monitored
Not suitable for every chemical or concentration
Does not remove all possible contaminants
Applications:
Selected educational laboratories
Limited chemical preparation tasks
Applications involving compatible chemicals and validated filtration systems
Ductless fume hoods should only be selected after evaluating the chemicals, concentrations, operating conditions, filter compatibility, and monitoring requirements.
They should not automatically replace ducted fume hoods in laboratories handling highly hazardous, unpredictable, or mixed chemical vapors.
2.3 PP Laboratory Fume Hood

A polypropylene (PP) fume hood is manufactured using polypropylene sheets and components.
PP is particularly useful in laboratories involving many corrosive acids and alkalis because of its chemical resistance.
Main Features:
PP internal structure
Chemical-resistant PP work surface
Corrosion-resistant construction
Suitable for selected acid and alkali applications
Optional PP sink and faucet
Compatible exhaust arrangements
Advantages:
Excellent resistance to many acids and alkalis
Good moisture resistance
Lightweight construction
Easy-to-clean surfaces
Suitable for corrosive laboratory environments
Disadvantages:
Lower heat resistance than many metal materials
Not suitable for every organic solvent
Structural design must account for PP material properties
Chemical compatibility must be checked for each application
Applications:
Chemistry laboratories
Acid digestion laboratories
Corrosive chemical preparation areas
Environmental testing laboratories
Selected chemical research facilities
PP fume hoods are particularly useful for applications involving compatible corrosive chemicals. However, the final design should consider chemical concentration, temperature, solvent exposure, and exhaust compatibility.
2.4 Steel Laboratory Fume Hood
Steel fume hoods are commonly manufactured using fabricated steel structures with protective powder-coated surfaces.
The internal liner and worktop can be selected according to the intended chemical application.
Main Features:
Fabricated steel cabinet structure
Powder-coated external finish
Chemical-resistant internal liner options
Movable sash
Integrated lighting
Optional service fixtures
External exhaust connection
Advantages:
Good mechanical strength
Durable structural construction
Flexible design and customization
Multiple color options
Suitable for many general chemical laboratory applications
Disadvantages:
Protective coatings can be damaged
Internal materials must be compatible with the chemicals
Not suitable for every highly corrosive environment without appropriate lining
Applications:
General chemistry laboratories
Educational laboratories
Research laboratories
Pharmaceutical facilities
Industrial testing laboratories
2.5 Walk-In Laboratory Fume Hood

A walk-in fume hood is designed for handling large equipment, tall apparatus, or experimental setups that cannot fit inside conventional bench-top fume hoods.
It typically features a larger enclosure and a floor-level or low-level access opening.
Main Features:
Large internal working space
Full-height enclosure
Large front access opening
Movable sash or access panels
External exhaust connection
Optional customized internal fittings
Advantages:
Accommodates large equipment
Provides greater internal working volume
Suitable for specialized experimental setups
Can be customized for different equipment dimensions
Disadvantages:
Requires more laboratory floor space
Higher exhaust volume may be required
Requires careful airflow design
Installation and transportation can be more complex
Applications:
Industrial laboratories
Large-scale chemical testing
Pilot-scale research
Specialized equipment testing
Laboratories handling bulky experimental apparatus
A walk-in fume hood is designed for equipment access, not as a space for personnel to enter and work inside during operation.
2.6 Floor-Mounted Laboratory Fume Hood

A floor-mounted fume hood is designed with a floor-supported structure and additional internal space for large equipment or specialized chemical operations.
Unlike conventional bench-top models, it can accommodate taller apparatus and equipment that require a larger working area.
Main Features:
Floor-mounted cabinet structure
Large internal working area
Customized working height
Optional lower storage compartments
External exhaust connection
Optional chemical-resistant lining
Advantages:
Suitable for large equipment
Flexible internal arrangements
Can be customized for specialized applications
Provides convenient equipment access
Applications:
Industrial laboratories
Research facilities
Chemical preparation areas
Large equipment testing laboratories
2.7 Multi-Face Laboratory Fume Hood

A multi-face fume hood is designed to provide access from multiple working sides.
Depending on the configuration, it can be installed as a central workstation shared by several operators.
Main Features:
Multiple access openings
Shared working area
Customized sash configurations
Centralized exhaust arrangement
Optional utility services
Different countertop materials
Advantages:
Supports collaborative laboratory operations
Allows access from multiple directions
Efficient use of central laboratory space
Suitable for selected shared experiments
Applications:
Educational laboratories
University research laboratories
Shared chemistry workstations
Specialized testing environments
Multi-face designs require careful airflow engineering to ensure that all operating openings maintain appropriate containment performance.
3. Laboratory Fume Hood Types Comparison
| Fume Hood Type | Main Feature | Typical Application |
|---|---|---|
| Ducted Fume Hood | External exhaust system | General chemical laboratories |
| Ductless Fume Hood | Built-in filtration system | Validated, compatible chemical applications |
| PP Fume Hood | Corrosion-resistant PP construction | Many acid and alkali applications |
| Steel Fume Hood | Strong metal structure | General laboratory applications |
| Walk-In Fume Hood | Large internal working space | Large experimental equipment |
| Floor-Mounted Fume Hood | Floor-supported design | Specialized equipment operations |
| Multi-Face Fume Hood | Access from multiple sides | Shared laboratory workstations |
The different categories are not mutually exclusive. For example, a PP fume hood can also be ducted, and a walk-in fume hood can be manufactured with a steel or PP construction depending on its application.
4. Main Components of a Laboratory Fume Hood
Understanding the structure of a fume hood helps buyers evaluate product specifications and manufacturing quality.
4.1 Sash
The sash is the movable front panel that allows operators to access the working area.
Common types include:
Vertical sliding sash
Horizontal sliding sash
Combination sash
The sash helps control the size of the working opening and contributes to containment performance.
4.2 Internal Liner
The internal liner forms the inner surfaces of the fume hood.
Common materials include:
PP
Chemical-resistant coated metal
Suitable laboratory-grade composite materials
The liner should be selected according to the chemicals and operating conditions.
4.3 Work Surface
The work surface supports laboratory equipment and chemical experiments.
Common materials include:
Epoxy resin
PP
Ceramic
Stainless steel
Other application-specific materials
4.4 Airflow Baffles
Baffles are installed inside the fume hood to help distribute airflow and reduce stagnant areas.
Their design is important for maintaining suitable airflow patterns.
4.5 Exhaust System
The exhaust system removes contaminated air from ducted fume hoods.
It generally includes:
Exhaust duct
Exhaust fan
Airflow control components
Suitable discharge arrangement
The duct and fan materials must be compatible with the chemicals being exhausted.
4.6 Lighting System
Integrated lighting provides visibility inside the working area.
Lighting components should be appropriately protected and selected for the intended environment.
4.7 Service Fixtures
Optional utility services may include:
Water faucets
Gas valves
Electrical sockets
Sink and drainage
Emergency service controls
The service arrangement should be confirmed according to laboratory requirements.
4.8 Airflow Monitoring and Alarm System
Airflow monitoring systems help indicate whether the fume hood is operating within its specified airflow conditions.
Common features include:
Airflow display
Low-airflow alarm
Audible and visual warnings
Sash position monitoring
Optional additional safety monitoring
5. How to Choose the Right Laboratory Fume Hood
Selecting a suitable fume hood requires evaluating the laboratory's actual operations.
5.1 Identify the Chemicals Being Used
Prepare a list of all chemicals used inside the fume hood.
Consider:
Chemical names
Concentrations
Operating temperatures
Quantities
Frequency of use
Potential reaction products
Chemical compatibility should be evaluated for the liner, worktop, sash components, ductwork, and exhaust fan.
5.2 Choose Between Ducted and Ductless Systems
A ducted fume hood is generally suitable for a wider range of chemical applications when properly designed.
A ductless fume hood may be considered when the chemicals and operating conditions are compatible with a validated filtration system.
Before selecting a ductless model, confirm:
Chemical compatibility with the filter
Expected chemical concentrations
Filter capacity and service life
Filter saturation monitoring
Replacement procedures
Appropriate use limitations
5.3 Select the Appropriate Construction Material
The fume hood material should match the chemical environment.
For example:
PP for many corrosive acid and alkali applications.
Powder-coated steel for many general laboratory applications.
Specialized internal liners for specific chemical exposures.
No single material is suitable for all chemicals.
5.4 Determine the Required Dimensions
Common laboratory fume hood widths include:
900 mm
1200 mm
1500 mm
1800 mm
Customized dimensions
The final dimensions should consider:
Laboratory room size
Equipment dimensions
Required working area
Number of operators
Exhaust requirements
Available installation space
5.5 Evaluate Airflow Performance
Airflow performance is one of the most important aspects of fume hood selection.
Consider:
Face velocity requirements
Airflow distribution
Containment performance
Sash opening dimensions
Exhaust volume
Alarm and monitoring systems
A suitable face velocity alone does not guarantee containment performance. Testing should follow the applicable project specifications and recognized testing methods.
5.6 Consider Installation Requirements
Before purchasing, confirm:
Available exhaust connections
Exhaust fan specifications
Duct routing
Electrical requirements
Water and drainage connections
Laboratory ceiling height
Maintenance access
5.7 Check Applicable Standards
Depending on the project location and specifications, relevant standards may include:
EN 14175 – Laboratory fume cupboards
ASHRAE 110 – Methods of testing performance of laboratory fume hoods
Applicable electrical safety standards
Local ventilation and laboratory safety requirements
Always confirm the required standard, applicable edition, and testing scope with the project specification.
6. Ducted vs Ductless Fume Hood: Which Is Better?
This is one of the most common questions when purchasing laboratory ventilation equipment.
Both systems have advantages, but their suitability depends on the chemical application.
Ducted Fume Hood
A ducted system removes contaminated air from the laboratory through an external exhaust system.
It is generally preferred for:
Diverse chemical applications
Applications with changing chemical inventories
Many demanding chemical operations
Processes where recirculating filtration is unsuitable
Ductless Fume Hood
A ductless system uses filters to remove specified contaminants before returning air to the laboratory.
It may be suitable for:
Well-defined chemical applications
Compatible chemicals
Controlled quantities and operating conditions
Applications with validated filtration and monitoring
Comparison Table
| Comparison | Ducted Fume Hood | Ductless Fume Hood |
|---|---|---|
| Exhaust Method | External exhaust | Internal filtration and recirculation |
| Ductwork | Required | Not normally required |
| Filter Replacement | Not the primary removal mechanism | Essential |
| Chemical Flexibility | Generally wider | Limited by filter compatibility |
| Installation | Requires exhaust infrastructure | More flexible |
| Maintenance | Fan and duct maintenance | Filter monitoring and replacement |
| Typical Application | General chemical laboratories | Validated compatible applications |
For laboratories handling highly hazardous chemicals, unknown mixtures, or substances that cannot be adequately captured by available filters, a properly designed ducted system is generally the safer choice.
7. Laboratory Fume Hood Materials: PP vs Steel
Material selection is particularly important for chemical resistance and long-term performance.
PP Fume Hood
PP fume hoods are suitable for many corrosive acid and alkali applications.
Advantages:
Excellent resistance to many acids and alkalis
Good moisture resistance
Lightweight construction
Suitable for corrosive environments
Limitations:
Lower heat resistance
Compatibility with organic solvents must be checked
Structural design requires appropriate reinforcement
Steel Fume Hood
Steel fume hoods provide a strong structural framework and flexible external finishes.
Advantages:
Good mechanical strength
Durable structural construction
Flexible design
Multiple color options
Limitations:
Coating damage may lead to corrosion
Internal lining must match chemical exposure
Not universally suitable for aggressive chemicals without appropriate protection
Material Comparison
| Feature | PP Fume Hood | Steel Fume Hood |
|---|---|---|
| Chemical Resistance | Excellent for many acids and alkalis | Depends on coating and liner |
| Mechanical Strength | Design-dependent | Generally high |
| Moisture Resistance | Excellent | Depends on protective finish |
| Heat Resistance | Limited | Generally higher, component-dependent |
| Weight | Generally lighter | Generally heavier |
| Typical Applications | Corrosive chemical environments | General laboratories |
The final choice should consider the entire fume hood assembly rather than only the external cabinet material.
8. Laboratory Fume Hood Maintenance and Safety
Regular inspection and maintenance are essential for maintaining fume hood performance.
8.1 Check Airflow Regularly
Monitor the airflow indicator and verify that the system operates within the specified range.
8.2 Inspect the Sash
Check the sash movement, counterbalance mechanism, glass condition, and operating stops.
8.3 Clean the Working Surface
Remove chemical residues using cleaning procedures compatible with the worktop material.
8.4 Inspect the Exhaust System
For ducted systems, inspect the exhaust fan, ductwork, connections, and discharge arrangements.
8.5 Monitor Filters
For ductless systems, follow the filter monitoring and replacement schedule specified by the manufacturer and based on actual chemical loading.
8.6 Arrange Performance Testing
Fume hoods should be commissioned and tested after installation and periodically according to applicable standards and institutional procedures.
Testing may include airflow measurements, visual checks, and containment performance evaluation.
8.7 Follow Safe Operating Procedures
Operators should:
Keep the sash at the designated working height.
Avoid placing unnecessary objects inside the hood.
Keep chemical containers appropriately positioned.
Avoid blocking airflow baffles.
Avoid using the hood for chemical storage.
Follow laboratory safety procedures.
9. Laboratory Fume Hood Customization
Different laboratory projects may require different fume hood dimensions, materials, and accessories.
BEST LAB provides customized fume hood solutions according to project requirements.
Customized Dimensions
Available widths include 900 mm, 1200 mm, 1500 mm, 1800 mm, and customized sizes.
Customized Materials
Options include:
PP construction
Powder-coated steel construction
Chemical-resistant internal liners
Suitable laboratory-grade countertops
Customized Sash Designs
Options may include:
Vertical sliding sash
Horizontal sliding sash
Combination sash
Customized Utility Services
Optional accessories include:
Water faucets
Laboratory sinks
Gas valves
Electrical sockets
Lighting systems
Airflow alarms
Customized Exhaust Systems
Ductwork, exhaust fans, and related components can be selected according to the required airflow, chemical compatibility, installation conditions, and project specifications.
Customized Storage Solutions
Selected models can be configured with suitable lower storage cabinets, including compatible chemical storage arrangements.
Technical Drawings and 3D Renderings
BEST LAB can provide technical drawings and 3D renderings to help customers review dimensions, structures, accessories, and installation arrangements before manufacturing.
10. Why Choose BEST LAB Laboratory Fume Hoods?
BEST LAB provides laboratory fume hoods and customized ventilation solutions for educational institutions, research facilities, pharmaceutical companies, and industrial laboratories.
Multiple Fume Hood Types
Our product range includes:
Ducted laboratory fume hoods
Ductless laboratory fume hoods
PP fume hoods
Steel fume hoods
Walk-in fume hoods
Floor-mounted fume hoods
Multi-face fume hoods
Flexible Material Options
Different construction materials and internal liners can be selected according to chemical compatibility and project requirements.
Customized Dimensions and Configurations
Fume hood width, depth, height, sash design, worktop, lower cabinets, and accessories can be customized.
Integrated Safety Features
Available configurations may include airflow monitoring, low-airflow alarms, lighting, and other suitable safety accessories.
Technical Support
BEST LAB provides technical drawings, product specifications, and 3D renderings to support project evaluation and equipment selection.
Complete Laboratory Furniture Solutions
In addition to fume hoods, BEST LAB supplies laboratory workbenches, chemical storage cabinets, laboratory sinks, countertops, and other laboratory furniture.
Conclusion
Laboratory fume hoods play an important role in protecting laboratory personnel from exposure to hazardous airborne substances.
Different fume hood types serve different purposes. Ducted systems are suitable for a wide range of chemical applications, ductless systems are designed for specific validated filtration applications, PP fume hoods are useful for many corrosive chemical environments, and walk-in and floor-mounted models accommodate larger equipment.
When selecting a laboratory fume hood, consider chemical compatibility, airflow performance, construction materials, exhaust requirements, working dimensions, and applicable safety standards.
A properly selected, installed, tested, and maintained fume hood can provide an important engineering control for laboratory safety.
Looking for a laboratory fume hood for your project?
BEST LAB provides ducted fume hoods, ductless fume hoods, PP fume hoods, steel fume hoods, walk-in fume hoods, and customized laboratory ventilation solutions.
Contact BEST LAB to discuss your chemical applications, fume hood dimensions, materials, airflow requirements, and project specifications.
Frequently Asked Questions
1. What is the main function of a laboratory fume hood?
A laboratory fume hood is designed to capture and remove hazardous airborne contaminants generated during laboratory operations, helping reduce operator exposure.
2. What are the main types of laboratory fume hoods?
Common types include ducted, ductless, PP, steel, walk-in, floor-mounted, and multi-face fume hoods.
3. What is the difference between a ducted and ductless fume hood?
A ducted fume hood removes contaminated air through an external exhaust system, while a ductless fume hood uses filtration to capture specified contaminants before recirculating air into the laboratory.
4. Which is better, a PP or steel fume hood?
PP is suitable for many corrosive acid and alkali applications, while steel provides good mechanical strength and is widely used for general laboratory applications. The final choice depends on chemical compatibility, temperature, and structural requirements.
5. What is the standard size of a laboratory fume hood?
Common widths include 900 mm, 1200 mm, 1500 mm, and 1800 mm. Customized dimensions are also available according to laboratory requirements.
6. What is a walk-in fume hood?
A walk-in fume hood is a large fume hood designed to accommodate tall or bulky laboratory equipment that cannot fit inside conventional bench-top models.
7. What is a PP fume hood used for?
PP fume hoods are commonly used in laboratories handling many compatible corrosive acids and alkalis.
8. What standards apply to laboratory fume hoods?
Commonly referenced standards include EN 14175 and ASHRAE 110. The applicable standard and testing requirements depend on the project specification and location.
9. Does a laboratory fume hood require an exhaust fan?
A ducted fume hood requires a suitable exhaust system, including an appropriately selected fan. Ductless models use an integrated filtration and airflow system instead.
10. Does BEST LAB manufacture customized laboratory fume hoods?
Yes. BEST LAB provides customized ducted, ductless, PP, steel, walk-in, floor-mounted, and multi-face fume hoods according to project requirements.
Follow Us
Any Questions? Get In Touch.
We Can Recommend Suitable Products According To Your Needs.